AVK COMBI-FLANGE FOR KIT, PN 10/16

For PE/PVC pipes, non-tensile, EPDM sealing

Contact

AVK Philippines Inc.

#70 West Avenue, Brgy. West Triangle 1104 Quezon City Metro Manila, PH

Combi-flange non-tensile unit for PVC and Bi-PVC pipes for drinking water and neutral liquids to max. 70°C

AVK’s combi-flange system comprises tensile combi-flanges for PE, PVC and ductile iron pipes as well as non-tensile combi-flanges for PVC, steel and ductile iron pipes. The design features a flexible positioning and chamfering of the pipe and a big angular deflection. The EPDM rubber sealings are approved for drinking water applications and the flanges are fusion bonded epoxy coating in compliance with DIN 3476 part 1 and EN 14901.

Variant 05/62-001
Connection: Flanged
Material: Ductile iron
DN: DN50 - DN300
PN: PN 10/16

Features

  • Flexible positioning of the pipe with the large buffer zone clearly marked on the sealing
  • Easy pipe chamfering allowing the pipe to be cut unevenly or out of angle, as long as it stays within the buffer zone
  • Barrel-shaped rubber sealing allows for up to ±3.5° deflection of the pipe
  • The pipe will not move inwards during installation which helps securing a tight connection
  • The EPDM rubber sealing is approved for drinking water applications
  • The rubber is resistant to water treatment chemicals and features an excellent compression set, meaning the ability to regain original shape
  • The sealing is supported by a sleeve of polypropylene
  • The special lip profile on the sealing provides hydraulic sealing and minimizes the compression on the pipe. Therefore, the combi-flange is also suitable for thin wall Bi-PVC pipes (Bi-PVC)
  • Flange of ductile iron is fusion bonded epoxy coating in compliance with DIN 3476 part 1 and EN 14901
  • Flange and gasket are packed as a complete unit
  • Design pressure 29 bar according to EN 12842. Working pressure max. 16 bar. Max. test pressure according to pipe standard.

Downloads

Datasheet
Installation, operation and maintenance manuals
Outline drawings

Reference nos. and dimensions:

Scroll for more info
AVK ref. no. DN
mm
Dd
mm
Flange
drilling
D
mm
L
mm
L9
mm
Theoretical
weight/kg
Notes
05-050-62-1600 50 63 PN10/16 165 97 27 1.7
05-075-62-1600 65 75 PN10/16 185 97 27 2.0
05-090-62-1600 80 90 PN10/16 200 98 27 2.3
05-110-62-1600 100 110 PN10/16 220 99 27 2.7
05-160-62-1600 150 160 PN10/16 285 105 27 3.9
05-200-62-1600 200 200 PN16 340 107 27 5.5
05-225-62-0600 200 225 PN10 340 115 27 6.2
05-225-62-1600 200 225 PN16 340 123 27 6.2
05-250-62-1600 250 250 PN16 395 123 27 7.0
05-280-62-1600 250 280 PN16 395 131 31 7.0 For Bi-PVC pipes a support bush is to be used.
05-315-62-1600 300 315 PN16 445 133 31 8.7 For Bi-PVC pipes a support bush is to be used.
2D/3D drawings
Enquiry
Scroll for more info

Components

1. Flange Ductile iron GJS-500-7 (GGG-50)
2. Seal EPDM rubber
3. Sleeve PP

Standards

  • EN 12842
  • Flange drilling to EN1092, PN10/16
0 Files In the package